The Film Heating Device of Orientaldream Co., Ltd. has been designated as an Excellent Product for its supply to the Supply Administration. For the first time in the business field of a film heating device, our technology and quality has been recognized by the Supply Administration and thus the Film Heating Device can be used by the government and public offices and state-run organizations for heating of their facilities. Hence, you may have a chance of seeing the Film Heating Device at the government place of the Supply Administration from now on.
- Construction heating
- Power Consumption 180W/㎡
- PET Molding Coating
- Excellent public Procurement
The Energy-Efficient heating by Using New Well-Being Material
Contrarily to the existing underfloor-heating room or other normal heating devices which transmit heat only to the floor, the sunlight system of the Film Heating Device is the heating system that allows the radiant heat of the far-infrared rays penetrates deep into the skin so that the warmth can be felt by all over the body.
The far-infrared rays shake minutely the molecules in our body more than 2,000 times per minute thereby generates heat, and through such vibrations the cellular tissues are activated and promote blood circulations are promoted, and it also helps the toxic substances and wastes are discharged from the body more efficiently.
For the heating system utilizing the Film Heating Device, it's very easy and safe to install it, and using the system is economical because its thermal efficiency is good. Also it has been proved to be an environmentally friendly heating system, for it uses electricity that does not create any environmental pollution.

|
Product name
|
Model
|
Size(mm)
|
Power Consumption(W)
|
Remarks
|
|
Film Heaters
|
ODP1500 ODP1200 ODP900 ODP600
|
1480 1280 980 660
|
300 240 200 120
|
±5%
|
| *The sizes of the products can be confirmed by our Test Certificate for which test we have requested from the Authorized Certificate Authority, and the size and test method of a test sample has been selected according to the KSA 3151(Random Sampling Method). |
How to install
- Inspections Required Prior to Installation
To confirm the consumption power of the Film Heating Device and the electricity used in the place of installation.
- Attachment of Insulation Material
To select the finishing material and other materials in consideration of the site situation.
- Attachment of Film Heating Device
For the length of the film heating device, cut and use it to the length corresponding with the capacity of the temperature controller. The cut area must be insulated with an insulating tape.
- Installation of the Temperature Controller and Sensor
To select and use electric wires of the certified product that meets the capacity and the cut area should be insulated and waterproof. The Sensor should be installed by fixing it with a tape in the place where heat collection is supposed to be made.
- Test Operation
To perform measurement of its voltage, current and surface temperature using a tester.
- Rearrange the Area and Post-Installation Requirements
Rearrange the area with removing foreign substances of metal property after its installation. Provide user with an instruction on how to use and precautions.
|
|
|
|
|
Attachment of Insulation Materials
|
Attachment of Film Heaters
|
Attachment of Temperature Controller
|
Comparison of Product Maintenance Cost
|
Film Heaters (Orientaldream)
|
Film Heaters (Other Company)
|
Oil boiler
|
Gas boiler (LNG)
|
Area 60㎡ 80% of Installation area 1mX1m=180W
1kw=69.9won 180WX60㎡X80%=8,640W Electricity Consumption for 60㎡=8.64kw Compensation rate of Temperature Adjuster: 35% Actual used quantity: 8.64kwX0.65=5.616kw
When used 30days with daily use of 10hours: 5.616kwX10hoursX30daysX 69.9won =117,767won
|
Area 60㎡ 80% of Installation area 1mX1m=240W
1kw=69.9won 240WX60㎡X80%=11,520W Electricity Consumption for 60㎡=11.52 Compensation rate of Temperature Adjuster: 35% Actual used quantity: 11.52kwX0.65=7.488kw
When used 30days with daily use of 10hours: 7.488kwX10hoursX30daysX 69.9won =157,023won
|
Area 60㎡ Boiler 10,000kcal/h
1liter=1,516won (Price subject to fluctuation) Consumption Quantity/hour =1.2liter Compensation rate of Temperature Adjuster: 35% Actual used quantity: 1.2literX0.65=0.78
When used 30days with daily use of 10hours: 0.78literX10hoursX30daysX 1,516won =354,744won
|
Area 60㎡ 1N㎥=10,500kcal 10,000kcal/h
1N㎥=712.2won (Price subject to fluctuation) Consumption Quantity/hour =1.08N㎥ Compensation rate of Temperature Adjuster: 35% Actual used quantity: 1.08N㎥X0.65=0.7
When used 30days with daily use of 10hours: 0.7N㎥X10hoursX30daysX 712.2won =149,562won
|
|
The Prices of Electricity, Kerosene and LNG are as of June 2008, Korea
|
|